DATA SET 18: H+, e-,
AND IONIC STRENGTH CORRECTION INFORMATION
One line (FREE FORMAT) contains the following five variables:
- SICOR = User's specified ionic strength for computing
activity coefficients. (This will be used as a constant
ionic strength if the user sets ICOR = 1 below).
- ICOR = Is ionic strength used to correct activity
coefficient?
0 = no,
1 = constant ionic strength is used (value specified by
the user above),
2 = variable ionic strength is used (as calculated by the
program).
- LNH = Location of the component H+ among
component list (in Data Sets 23 and 24), 0 if not present.
- LNG = Location of the gas component among component list
(in Data Sets 23 and 24), 0 if not present.
- LNE = Location of the component e- among
component list (in Data Sets 23 and 24), 0 if not present.
v1.0 - 1/14/1999