DATA SET 6b. WATER THERMODYNAMIC PROPERTIES AND TEMPERATURE CORRECTION FUNCTIONS


This data set is needed only when ISHEAT (specified in DATA SET 6a) > 0.

Line 1: includes the following five real numbers:

  1. SPHEAT = Reference groundwater specific heat (L**2/T**2/oK).
  2. GASCNT = Ideal gas constant (ML**2/T**2/oK/mole).
  3. RHO_PW = Reference water density (M/L**3).
  4. AMU_PW = Reference water dynamic viscosity (M/LT).
  5. TEMPREF = Reference temperature for density correction (oK).

Line 2: include the following one integer number.

NRHO = Number of coefficients for the density correction function.

Line 3: includes NRHO real numbers of the following coefficients.

RHOC(I), I=1,NRHO, is the I-th coefficient of the density correction function.

Line 4: includes the following one integer number.

NMU = Number of coefficients for dynamic viscosity correction function.

Line 5: include NMU real numbers of the following coefficients.

AMUC(I), I=1,NMU, is the I-th coefficient of the viscosity correction function.

Line 6: includes the following one single integer number.

NLAMBDA = Number of coefficient for the apparent heat conductivity correction function.

Line 7: includes the following NLAMBDA real numbers.

DMBC(I), I=1,NLAMBDA, is the I-th coefficient of the apparent heat conductivity correction function.


v1.0 - 1/14/1999

Jin-Ping Gwo, email: jgwo@umbc.edu